What this article helps you consider
- Define the measurements precisely
- Consider how the formulation holds water
- Select the method for the question
Define the measurements precisely
Water content expresses the amount of water in a sample on a defined basis, commonly as a mass percentage. The result depends on the procedure and whether water is released or extracted completely. Water activity, usually written as aw, is the ratio of water-vapour pressure over the sample to that over pure water at the same temperature.
At equilibrium, water activity corresponds to equilibrium relative humidity divided by 100. It is not another way of expressing water percentage. USP chapters 921 and 922 address different measurements, while ISO 18787 provides a food-focused water-activity framework. R45R46R48
Consider how the formulation holds water
Ingredients interact with water differently. Salts, sugars, polymers and crystalline hydrates can affect its thermodynamic state and the product’s physical behaviour. Consequently, two formulations with the same measured water content can have different water activities. Their relationships can also change with temperature or physical-state transitions.
The illustration uses invented sorption curves to illustrate that water content and water activity are related in a material-specific way. The curves are not a specification or a prediction for any named ingredient. Actual sorption studies require controlled temperature, an appropriate equilibration approach and consideration of adsorption and desorption history.
Invented sorption data at a hypothetical fixed temperature. No product specification or microbial safety threshold.
Select the method for the question
Karl Fischer titration is useful for water determination when the chemistry and sample preparation are suitable. Direct addition, extraction or an oven approach may be needed depending on the matrix. Investigate incomplete release, side reactions and background drift where they could affect the result.
Loss on drying measures mass lost under specified conditions and can include solvents or other volatile matter. A loss-on-drying value should not automatically be labelled water content. Conversely, a water-activity instrument does not establish the total water present. Record the method and units so that similar-looking numbers are not compared as equivalent results. R46R47
Control temperature and equilibration
Water-activity measurements are sensitive to temperature and to whether the sample and sensor have reached a suitable equilibrium. Volatile formulation components can interfere with some instrument technologies. Choose calibration checks and handling procedures that are appropriate to the sample and intended measurement range.
A powder removed from a dry environment can gain moisture during an extended laboratory preparation. A warm sample can also produce an unstable headspace reading. Define sampling, transfer and equilibration conditions, and assess whether handling changes the attribute being measured.
Connect the result to the failure mechanism
Moisture can influence flow, caking, tablet strength, coating behaviour and chemical reactions. Water activity informs some microbial growth assessments, but low water activity does not mean that a product is sterile or free from viable pathogens. Organisms can survive conditions that do not support their growth. Category-specific microbiological requirements still apply.
Consider a hypothetical chewable that becomes sticky despite a relatively small change in total water. Investigate the formulation’s moisture response, environmental exposure and packaging rather than dismissing the change because the water percentage remains low. The relevant transition may be nonlinear.
Build controls around product evidence
Decide whether water content, water activity or both are needed for the particular formulation. Establish limits through relevant development, stability and safety evidence instead of borrowing a threshold from a different matrix. Review the choice after major ingredient, process or packaging changes.
Stabicon can connect moisture characterisation with formulation and stability investigations, helping teams select measurements that explain the product’s behaviour rather than simply add another number to a certificate.
References & further reading
Read the source in its stated scope. Requirements, amendments and compendial editions depend on the product and target market. Draft guidance is identified separately.
- R45USP General Chapter 922 Water Activity
Official publisher preview. Water activity is distinct from total water content.
- R46USP General Chapter 921 Water Determination
Official publisher preview. Use the current applicable edition and corrections.
- R47USP General Chapter 731 Loss on Drying
Official publisher preview. Measures volatile mass loss under specified conditions.
- R48ISO 18787 Foodstuffs Determination of Water Activity
Official standard information. Food-matrix water-activity measurement.
From insight to a defined programme
Bring your next technical question.
Share your formulation, testing objective or development challenge. Stabicon can review the context and define a suitable scope of work.
Discuss this topic with Stabicon